metadata.dc.type: | Dissertação |
Title: | Perfuração de imobilizações ortopédicas em gesso tradicional e sintético e consequências sobre a resistência mecânica |
metadata.dc.creator: | Esmanhotto, Andre |
metadata.dc.contributor.advisor1: | Pinheiro, Luís Antonio |
metadata.dc.contributor.advisor-co1: | Novatski, Andressa |
metadata.dc.contributor.referee1: | Sabino, Simone do Rocio Ferraz |
metadata.dc.contributor.referee2: | Bandeca, Shelon Cristina Souza |
metadata.dc.description.resumo: | A confecção de imobilizações ortopédicas é procedimento frequente em pronto socorro. Tais imobilizações são tradicionalmente confeccionadas em gesso tradicional (sulfato de cálcio) ou em gesso sintético (fibra de vidro e poliuretano), em formato circunferencial fechado, não permitindo a ventilação do membro imobilizado, deste modo causando mal cheiro, prurido, ressecamento da pele, sensação de calor, impedindo a higiene e a visualização da pele, predispondo e agravando infecções e reações cutâneas. No sentido de superar estes inconvenientes, a indústria de materiais ortopédicos tem lançando produtos novos com múltiplas perfurações, a fim de se obter melhor ventilação da pele e permitir a inspeção da superfície do membro. Entretanto, tais produtos têm alto custo e pouca disponibilidade. Neste contexto, questiona-se tais perfurações poderiam ser realizadas em materiais comumente utilizados na ortopedia: gesso tradicional e gesso sintético. O objetivo deste trabalho foi estudar as consequências mecânicas da perfuração do gesso tradicional e gesso sintético, como um primeiro passo no sentido do desenvolvimento de imobilizações perfuradas neste tipo de material, já que não foram encontrados trabalhos prévios a este respeito. Considerando-se que o gesso sintético tem resistência mecânica superior ao gesso tradicional, a hipótese é de que o gesso sintético, mesmo após ser perfurado, ainda tenha resistência próxima ao gesso tradicional, o que viabilizaria seu uso, mesmo perfurado. Foram realizados ensaios de laboratório em máquinas de flexão em 3 pontos e de impacto, com amostras de gesso tradicional, gesso sintético e gesso sintético perfurado. Os resultados mostram que o gesso sintético, mesmo perfurado, mantém resistência mecânica em níveis próximos ao gesso tradicional. Entretanto, são necessários estudos adicionais sobre o tamanho, localização, formato e modo de confecção das perfurações. |
Abstract: | Orthopaedic immobilization is a frequently performed procedure in emergency rooms. Traditionally, a circular closed cast made of plaster of Paris or fiberglass is made, in a circular closed shape, not allowing ventilation of the immobilized limb and causing bad smell, itching, skin dryness and feeling of heat, also preventing hygiene and visualization of the skin status, predisposing and aggravating infections and skin reactions. In order to overcome these drawbacks, the orthopaedic materials industry has been releasing new products with multiple perforations, however, such materials are expensive and little available. In this context, it is questionable whether such perforations could be performed in materials commonly used in orthopaedics: plaster of Paris and fiberglass. The aim of this study was testing the mechanical the mechanical consequences of that such perforations on plaster of Paris and fiberglass, as a first step towards the development of perforated immobilizations in this type of material. Considering that fiberglass has greater mechanical resistance than plaster of Paris, the hypothesis is that perforated fiberglass has similar resistance to plaster of Paris. Three-point bending and impact tests were performed with samples of unperforated plaster, fiberglass plaster and perforated fiberglass plaster. The results show that synthetic plaster, even perforated, maintains mechanical resistance at levels close to plaster of Paris. Additional studies are needed. |
Keywords: | Imobilização resistência de materiais moldes cirúrgicos aparelhos ortopédicos inovação Immobilization material Resistance surgical casts orthotic devices diffusion of Innovation |
metadata.dc.subject.cnpq: | CNPQ::CIENCIAS DA SAUDE |
metadata.dc.language: | por |
metadata.dc.publisher.country: | Brasil |
Publisher: | Universidade Estadual de Ponta Grossa |
metadata.dc.publisher.initials: | UEPG |
metadata.dc.publisher.department: | Setor de Ciências Biológicas e da Saúde |
metadata.dc.publisher.program: | Programa de Pós-Graduação em Ciências da Saúde |
Citation: | ESMANHOTTO, Andre. Perfuração de imobilizações ortopédicas em gesso tradicional e sintético e consequências sobre a resistência mecânica. 2022. Dissertação (Mestrado em Ciências da Saúde), Universidade Estadual de Ponta Grossa, Ponta Grossa, 2022. |
metadata.dc.rights: | Acesso Aberto Attribution-NonCommercial-NoDerivs 3.0 Brazil |
metadata.dc.rights.uri: | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ |
URI: | http://tede2.uepg.br/jspui/handle/prefix/3994 |
Issue Date: | 21-Dec-2022 |
Appears in Collections: | Programa de Pós - Graduação em Ciências da Saúde |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Andre Esmanhotto.pdf | dissertação completa em pdf | 1.78 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License