Please use this identifier to cite or link to this item: http://tede2.uepg.br/jspui/handle/prefix/1802
metadata.dc.type: Dissertação
Title: Caracterização físico-quimica e avaliação de biocompatibilidade de biovidros estudo laboratorial e histomorfométrico em ratos
metadata.dc.creator: Cruz, Ariadne Cristiane Cabral da
metadata.dc.contributor.advisor1: Santos, Fábio André dos
metadata.dc.contributor.referee1: Pilatti, Gibson Luiz
metadata.dc.contributor.referee2: Cirelli, Joni Augusto
metadata.dc.description.resumo: O presente trabalho se propôs a avaliar as características físico-químicas e a biocompatibilidade do biovidro desenvolvido pelo departamento de Química da UEPG (Biovidro UEPG) e compará-lo com o PerioGlas® e Biogran®. Realizou-se a caracterização físico-química através da microscopia eletrônica de varredura (MEV) (tamanho e morfologia das partículas); microscopia eletrônica de varredura/ energia dispersiva de Raios X (MEV/EDX) (elementos químicos); difratometria de Raios X (DFR) (estrutura); fluorescência de Raios X FRX (elementos químicos). Para o teste de biocompatibilidade utilizou-se 100 ratos, sendo: GI- PerioGlas® - 25 animais; GIIBiogran ® - 25 animais; GIII- Biovidro UEPG - 25 animais; GIV- Controle (procedimento cirúrgico sem implantação do biomaterial) - 25 animais. Avaliou-se os animais em 7, 15, 21, 45 e 60 dias. Através de histomorfometria determinou-se o tamanho da reação inflamatória, tamanho dos grânulos, presença e quantidade de células polimorfonuclear (PMN), mononuclear (MN) e fibroblasto (F). Os resultados mostraram que as partículas dos três materiais apresentaram-se não uniformes e com rugosidade superficial. Os grânulos de PerioGlas® apresentaram-se com tamanho médio de 222,00±40,64µm. O Biogran® com 385,09±68,51µm. E o Biovidro-UEPG com 102,86±36,22µm. Houve diferença significativa no tamanho dos grânulos (p<0,001- ANOVA). Identificou-se nas três amostras cálcio, oxigênio, sódio, fósforo e sílica, agrupados em óxido de sílica, óxido de sódio, óxido de cálcio e óxido de fósforo. Os materiais mostraram-se não cristalinos e com pontos de cristalização. Houve diferença significativa no tamanho da reação inflamatória entre os grupos, tempos e interação (grupo*tempo) (p<0,001). Na contagem de MN não houve diferença significativa entre os grupos (p=0,117), havendo entre os tempos (p<0,001) e interação (p=0,022). Houve diferença significativa (p<0,001) na contagem de PMN entre os tempos, grupos e interação. A contagem de F não mostrou diferença significativa entre os grupos (p=0,131) e interação (p=0,665), havendo diferença entre os tempos (p=0,008). Houve diferença significativa no tamanho dos grânulos entre os grupos, tempo e interação (p<0,001). Concluiu-se que os três materiais apresentaram-se biocompatíveis e bioreabsorvíveis, sem indício de capacidade osteoindutora.
Abstract: The purpose of this study was to evaluate physic-chemical characteristics and the biocompatibility of the bioglass, developed by the UEPG Chemistry Department, (UEPG Bioglass) and compare it with the PerioGlas® e Biogran®. The physicchemical characterization was made by scanning electron microscopy (SEM) (size and morphology of particles); scanning electron microscopy/energy dispersive X Ray (MEV/EDAX) (chemical elements); X Ray diffractometry (DRX) (structure); X Ray fluorescence (FRX) (chemical elements) For the biocompatibility test was used 100 rats: Gl-PerioGlas® - 25 animals; Gll – Biogran® - 25 animals; Glll – Biovidro UEPG – 25 animals; GIV – Control (surgical procedure without implantation of biomaterial) – 25 animals. The animals were evaluated at 7, 15, 21, 45 and 60 days. It was used histomorphometric analysis to determine the size of inflammatory reaction, size of granules, the presence and quantity of polymorphonuclear cells (PMN), mononuclear (MN) and fibroblast (F). The results shown that the particles of the three materials were irregular with superficial roughness. The medial size of PerioGlas® granules was 222,00±40,64 µm. The Biogran® granules with 385.09±68.51µm. And the UEPG Bioglass was 102.86±36.22µm. There was significant difference in the size of granules (p<0.001-ANOVA). The three samples presented calcium, oxygen, sodium, phosphorus and silica, aggregated on silica oxide, sodium oxide, calcium oxide and phosphorus oxide. The materials were no crystalline and with crystalline points in their surfaces. There was significant difference on size of inflammatory reaction between groups, times and interaction (group*time) (p<0.001). There was not significant difference between on the count of MN between groups (p=0.117), there was difference between times (p<0.001) and interaction (p=0.022). There was significant difference (p<0.001) on the count of PMN between the times, groups and interaction. There was not significant difference on the count of F between the groups (p=0.131) and interaction (p=0.665), with significant difference between the times (p=0.008). There was significant difference on granules size between the groups, time and interaction (p<0.001). It was concluded that the three materials were biocompatible and bioreabsorbable, without sign of osteoinducture capacity.
Keywords: materiais biocompatíveis
vidro
substitutos ósseos
biocompatible materials
glass
bone substitutes
metadata.dc.subject.cnpq: CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
metadata.dc.language: por
metadata.dc.publisher.country: BR
Publisher: UNIVERSIDADE ESTADUAL DE PONTA GROSSA
metadata.dc.publisher.initials: UEPG
metadata.dc.publisher.department: Clinica Integrada, Dentística Restauradora e Periodontia
metadata.dc.publisher.program: Programa de Pós-Graduação em Odontologia
Citation: CRUZ, Ariadne Cristiane Cabral da. Caracterização físico-quimica e avaliação de biocompatibilidade de biovidros estudo laboratorial e histomorfométrico em ratos. 2004. 124 f. Dissertação (Mestrado em Clinica Integrada, Dentística Restauradora e Periodontia) - UNIVERSIDADE ESTADUAL DE PONTA GROSSA, Ponta Grossa, 2004.
metadata.dc.rights: Acesso Aberto
URI: http://tede2.uepg.br/jspui/handle/prefix/1802
Issue Date: 17-Jun-2004
Appears in Collections:Programa de Pós - Graduação em Odontologia

Files in This Item:
File SizeFormat 
AriadneCristiane.pdf1.12 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.