Please use this identifier to cite or link to this item:
http://tede2.uepg.br/jspui/handle/prefix/4115
metadata.dc.type: | Dissertação |
Title: | Efeito de interferências oclusais excêntricas artificias no Desempenho mastigatório: um ensaio clínico randomizado duplo-cego |
metadata.dc.creator: | Silva, Fernanda Pereira da |
metadata.dc.contributor.advisor1: | Ayala, Alfonso Sánchez |
metadata.dc.contributor.referee1: | Santos, Fábio André dos |
metadata.dc.contributor.referee2: | Franco, Ana Paula Gebert de Oliveira |
metadata.dc.description.resumo: | As interferências oclusais levam a alterações na cinemática mandibular para compensar e melhorar a função. No entanto, o efeito particular de diferentes tipos de distúrbios excêntricos na capacidade de cominuição ainda não foi considerado. Determinar o efeito imediato das interferências oclusais excêntricas no desempenho mastigatório. Este ensaio clínico cruzado incluiu 12 dentados hígidos, com idade de 25,2 ± 3,3 anos, que foram submetidos a sete tipos de interferências: laterotrusiva unilateral e bilateral, mediotrusiva unilateral e bilateral, protrusiva, dummy e controle (sem interferência). As interferências foram planejadas em articulador semi-ajustável, confeccionado em resina composta e aderido nos primeiros molares inferiores mantendo máxima intercuspidação dos sujeitos. O desempenho mastigatório e a taxa de mastigação até 20 ciclos foram avaliados pela cominuição do alimento teste de silicone e pelo método da tamisagem. Para cada condição, as interferências permaneceram em boca até a finalização dos testes, após isso, um período de washout de uma semana foi utilizada. Indivíduos em condições unilateral (4,94 ± 0,41 mm) e bilateral (4,81 ± 0,49 mm) laterotrusiva, mediotrusiva bilateral (4,65 ± 0,50 mm) e protrusiva (4,83 ± 0,54 mm) apresentaram os maiores tamanhos médios de partículascominutivas (p < 0,05), enquanto com as configurações controle (4,01 ± 0,52 mm) e dummy (4,18 ± 0,58 mm) apresentaram os menores valores (p < 0,05). Apenas com interferências laterotrusivas unilateral e bilaterais, os indivíduos apresentaram menor dispersão de partículas cominutivas (p < 0,05). Não houve diferenças entre ascondições (p = 0,1944) para os dados de taxa de mastigação. Os achados sugerem que interferências oclusais excêntricas diminuem o desempenho mastigatório. |
Abstract: | Occlusal interferences lead to changes on mandibular kinematic in order to compensate and improve function. However, the particular effect for different kind of eccentric disturbances on comminuting capacity was still not considered. To determine the immediate effect of eccentric occlusal interferences on masticatory performance. This crossover clinical trial included 12 healthy dentate, aged 25.2 ± 3.3 years, whichwere submitted to seven kinds of interferences: uni- and bilateral laterotrusive, uni- and bilateral mediotrusive, protrusive, dummy, and control (no interference). The interferences were planned in semi-adjustable articulator, fabricated with composite resin and adhered on lower first molars maintaining maximum intercuspation of subjects. Masticatory performance and chewing rate until 20 cycles was evaluated by comminution of silicone test food and multiple sieve method. For each condition, interferencesremained in mouth until complete the tests, after that, 1 week was used as a washout period. Subjects in uni- (4.94 ± 0.41 mm) and bilateral (4.81 ± 0.49 mm) laterotrusive, bilateral mediotrusive (4.65 ± 0.50 mm) and protrusive (4.83 ± 0.54 mm) conditions showed the highercomminuted median particle sizes (p < 0.05), while with the control (4.01 ± 0.52 mm) and dummy (4.18 ± 0.58 mm) settings they presented the lower values (p < 0.05). Only with uni- and bilateral laterotrusive interferences, subjects showed narrower dispersion of comminuted particles (p < 0.05). There were no differences among conditions (p = 0.1944) to chewing rate data. The findings suggested that eccentric occlusal interferences decrease the masticatory performance. |
Keywords: | Oclusão dentária interferência oclusal desempenho mastigatório taxa de mastigação alimento teste de silicone ajuste oclusal Dental occlusion occlusal interference masticatory performance chewing rate silicone test food occlusal adjustment |
metadata.dc.subject.cnpq: | CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
metadata.dc.language: | por |
metadata.dc.publisher.country: | Brasil |
Publisher: | Universidade Estadual de Ponta Grossa |
metadata.dc.publisher.initials: | UEPG |
metadata.dc.publisher.department: | Departamento de Odontologia |
metadata.dc.publisher.program: | Programa de Pós-Graduação em Odontologia |
Citation: | SILVA, Fernanda Pereira da. Efeito de interferências oclusais excêntricas artificiais no desempenho mastigatório: um ensaio clínico randomizado duplo-cego. 2022. Dissertação (Mestrado em Odontologia) - Universidade Estadual de Ponta Grossa, Ponta Grossa, 2022. |
metadata.dc.rights: | Acesso Aberto Attribution-NonCommercial-NoDerivs 3.0 Brazil |
metadata.dc.rights.uri: | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ |
URI: | http://tede2.uepg.br/jspui/handle/prefix/4115 |
Issue Date: | 19-Oct-2022 |
Appears in Collections: | Programa de Pós - Graduação em Odontologia |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Fernanda Pereira da Silva.pdf | dissertação completa em pdf | 1.96 MB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License